Error list
for STKO v.3.1.0
analysis_steps error list

The following is a list of analysis_steps errors that can occur while using STKO (Scientific Toolkit for OpenSees).

For each error, a brief description and a possible solution to resolve it is provided. In case the error is not in the list or if the proposed solution has no effect, please post in our forum.

error codecommanderror messagesolution
AnalysesCommand variable with incorrect value The AnalysesCommand presents an empty timeseries path.


Make sure that a timeseries path is selected.


AnalysesCommand incorrect size of variables The AnalysesCommand requires that the timeseries for Cyclic displacement control should have at least 2 values.


Make sure that the timeseries for Cyclic displacement control have at least 2 values.


AnalysesCommand incorrect size of variables The AnalysesCommand requires that list_value and list_Time have the same size.


Make sure that the variables list_value and list_Time have the same size.


AnalysesCommand incorrect size of variables The AnalysesCommand requires that the selection set for DisplacementControl must contain 1 vertex.


Make sure that the selection set for DisplacementControl contains 1 vertex.


AnalysesCommand variable with incorrect value The AnalysesCommand requires that max factor should be greater than or equal to 1.


Make sure that max factor has a value greater than or equal to 1.


AnalysesCommand variable with incorrect value The AnalysesCommand requires that min factor should be between 0 (inclusive) and 1 (inclusive).


Make sure that min factor has a value between 0 (inclusive) and 1 (inclusive).


AnalysesCommand variable with incorrect value The AnalysesCommand requires that max factor incr should be greater of 1.


Make sure that max factor incr has a value greater of 1.


AnalysesCommand variable with incorrect value The AnalysesCommand requires that min factor incr should be between 0 (inclusive) and 1.


Make sure that min factor incr has a value between 0 (inclusive) and 1.


integrator incorrect or missed selection set The integrator requires that a selection set be specified for the control node of the ParallelDisplacementControl.


Make sure that a selection set is specified for the control node of the ParallelDisplacementControl integrator.


integrator incorrect or missed selection set The integrator requires that the selection set for ParallelDisplacementControl must contain 1 geometry.


Make sure that the selection set for the ParallelDisplacementControl integrator contains 1 geometry.


integrator incorrect or missed selection set The integrator requires that the selection set for ParallelDisplacementControl must contain 1 vertex.


Make sure that the selection set for the ParallelDisplacementControl integrator contains 1 vertex.


integrator incorrect or missed selection set The integrator requires that a selection set be specified for the control node of the DisplacementControl.


Make sure that a selection set is specified for the control node of the DisplacementControl integrator.


integrator incorrect or missed selection set The integrator requires that the selection set for DisplacementControl must contain 1 geometry.


Make sure that the selection set for the DisplacementControl integrator contains 1 geometry.


integrator incorrect or missed selection set The integrator requires that the selection set for DisplacementControl must contain 1 vertex.


Make sure that the selection set for the DisplacementControl integrator contains 1 vertex.


test unknown attribute name Unknown attribute name for test command.


Make sure that the attribute name is one of the following: NormUnbalance, NormDispIncr, EnergyIncr, Relative Norm Unbalance Test, Relative Norm Displacement Increment Test, Total Relative Norm Displacement Increment Test, Relative Energy Increment Test, Fixed Number of Iterations.


ASDAbsorbingBoundaryActivate incorrect spatial dimensions In the same file there are both 2D and 3D ASDAbsorbingBoundary elements.


Make sure that in the file there are only 2D or 3D ASDAbsorbingBoundary elements. It is not possible to mix the spatial dimensions.


monitor variable with incorrect value The monitor presents an empty Custom Name.


Make sure that the Custom Name is not empty.


monitor no CAE document Create at least one CAE document.


At the moment this error will never be launched (as STKO is set up).


monitor variable with incorrect value The monitor presents a name that has already been used.


Make sure that the name provided is unique.


RayleighDampingTester Xobject is Null or has no parent component The RayleighDampingTester presents a Null Xobject or has no parent component.


Make sure that an Analysis Step has been set.


RayleighDampingTester Xobject is Null or has no parent component The RayleighDampingTester presents a Null Xobject or has no parent component.


Make sure that an Analysis Step has been set.


RayleighDampingTester no CAE document Create at least one CAE document.


At the moment this error will never be launched (as STKO is set up).


constraintPattern no CAE document Create at least one CAE document.


At the moment this error will never be launched (as STKO is set up).


loadPattern no CAE document Create at least one CAE document.


At the moment this error will never be launched (as STKO is set up).


loadPattern Xobject is Null or has no parent component The loadPattern presents a Null Xobject or has no parent component.


Make sure that an Analysis Step has been set.


loadPattern Xobject is Null or has no parent component The loadPattern presents a Null Xobject or has no parent component.


Make sure that an Analysis Step has been set.


loadPattern Xobject is Null or has no parent component The loadPattern presents a Null Xobject or has no parent component.


Make sure that an Analysis Step has been set.


loadPattern Xobject is Null or has no parent component The loadPattern presents a Null Xobject or has no parent component.


Make sure that an Analysis Step has been set.


MultipleSupport Xobject is Null or has no parent component The MultipleSupport presents a Null Xobject or has no parent component.


Make sure that an Analysis Step has been set.


MPCORecorder variable with incorrect value The MPCORecorder presents an empty file name.


Make sure that the file name is not empty.


MPCORecorder variable with incorrect value The specified directory in MPCORecorder does not exists.


Make sure that the specified directory already exists.


MPCORecorder variable with incorrect value The MPCORecorder presents an empty file name.


Make sure that the file name is not empty.


MPCORecorder variable with incorrect value The MPCORecorder presents a file name with invalid characters.


Make sure that the file name contains only Unicode characters.